1 | 1 | # Mapping internal data / REST endpoints
|
2 | 2 | This table helps to define which Solis REST API endpoints provide which information used for monitoring.
|
3 | 3 |
|
4 |
| -| fieldKey | fieldType | Unit | REST endpoint | API | |
5 |
| -|--------------------------|-----------|------|----------------|------------------------------| |
6 |
| -| AC_Current | float | A | inverterDetail | (iAc1+iAc2+iAc3)/3 | |
7 |
| -| AC_Frequency | float | Hz | inverterDetail | fac | |
8 |
| -| AC_Power | float | W | inverterDetail | pac | |
9 |
| -| AC_Voltage | float | V | inverterDetail | (uAc1+uAc2+uAc3)/3 | |
10 |
| -| Annual_Energy_Used | float | kWh | inverterYear | energy - gridSellEnergy | |
11 |
| -| Annual_Generation | float | kWh | inverterYear | energy | |
12 |
| -| Battery_Charge_Percent | float | | | | |
13 |
| -| Consumption_Energy | float | kWh | inverterDetail | homeLoadTotalEnergy | |
14 |
| -| Consumption_Power | float | W | inverterDetail | familyLoadPower | |
15 |
| -| DC_Current1 | float | A | inverterDetail | iPv1 | |
16 |
| -| DC_Current2 | float | A | inverterDetail | iPv2 | |
17 |
| -| DC_Current3 | float | A | inverterDetail | iPv3 | |
18 |
| -| DC_Current4 | float | A | inverterDetail | iPv4 | |
19 |
| -| DC_Power_PV1 | float | W | inverterDetail | pow1 | |
20 |
| -| DC_Power_PV2 | float | W | inverterDetail | pow2 | |
21 |
| -| DC_Power_PV3 | float | W | inverterDetail | pow3 | |
22 |
| -| DC_Power_PV4 | float | W | inverterDetail | pow4 | |
23 |
| -| DC_Voltage_PV1 | float | V | inverterDetail | uPv1 | |
24 |
| -| DC_Voltage_PV2 | float | V | inverterDetail | uPv2 | |
25 |
| -| DC_Voltage_PV3 | float | V | inverterDetail | uPv3 | |
26 |
| -| DC_Voltage_PV4 | float | V | inverterDetail | uPv4 | |
27 |
| -| Daily_Energy_Used | float | kWh | inverterDetail | eToday - gridSellTodayEnergy | |
28 |
| -| Daily_Generation | float | kWh | inverterDetail | eToday | |
29 |
| -| Generation_Last_Month | float | kWh | inverterMonth | energy | |
30 |
| -| Inverter_Temperature | float | °C | inverterDetail | inverterTemperature | |
31 |
| -| Monthly_Energy_Used | float | kWh | inverterMonth | energy - gridSellEnergy | |
32 |
| -| Monthly_Generation | float | kWh | inverterDetail | eMonth | |
33 |
| -| Power_Grid_Total_Power | float | W | inverterDetail | pSum | |
34 |
| -| Total_Energy_Purchased | float | kWh | inverterDetail | gridPurchasedTotalEnergy | |
35 |
| -| Total_Generation | float | kWh | inverterDetail | eTotal | |
36 |
| -| Total_On_grid_Generation | float | kWh | inverterDetail | gridSellTotalEnergy | |
37 |
| -| updateDate | integer | | inverterDetail | dataTimestamp | |
| 4 | +| fieldKey | fieldType | Unit | REST endpoint | API | |
| 5 | +|--------------------------|-----------|------|------------------|------------------------------| |
| 6 | +| AC_Current | float | A | inverterDetail | (iAc1+iAc2+iAc3)/3 | |
| 7 | +| AC_Frequency | float | Hz | inverterDetail | fac | |
| 8 | +| AC_Power | float | W | inverterDetail | pac | |
| 9 | +| AC_Voltage | float | V | inverterDetail | (uAc1+uAc2+uAc3)/3 | |
| 10 | +| Annual_Energy_Used | float | kWh | inverterDetail | eYear - gridSellYearEnergy | |
| 11 | +| Annual_Generation | float | kWh | inverterDetail | eYear | |
| 12 | +| Battery_Charge_Percent | float | | | | |
| 13 | +| Consumption_Energy | float | kWh | inverterDetail | homeLoadTotalEnergy | |
| 14 | +| Consumption_Power | float | W | inverterDetail | familyLoadPower | |
| 15 | +| DC_Current1 | float | A | inverterDetail | iPv1 | |
| 16 | +| DC_Current2 | float | A | inverterDetail | iPv2 | |
| 17 | +| DC_Current3 | float | A | inverterDetail | iPv3 | |
| 18 | +| DC_Current4 | float | A | inverterDetail | iPv4 | |
| 19 | +| DC_Power_PV1 | float | W | inverterDetail | pow1 | |
| 20 | +| DC_Power_PV2 | float | W | inverterDetail | pow2 | |
| 21 | +| DC_Power_PV3 | float | W | inverterDetail | pow3 | |
| 22 | +| DC_Power_PV4 | float | W | inverterDetail | pow4 | |
| 23 | +| DC_Voltage_PV1 | float | V | inverterDetail | uPv1 | |
| 24 | +| DC_Voltage_PV2 | float | V | inverterDetail | uPv2 | |
| 25 | +| DC_Voltage_PV3 | float | V | inverterDetail | uPv3 | |
| 26 | +| DC_Voltage_PV4 | float | V | inverterDetail | uPv4 | |
| 27 | +| Daily_Energy_Used | float | kWh | inverterDetail | eToday - gridSellTodayEnergy | |
| 28 | +| Daily_Generation | float | kWh | inverterDetail | eToday | |
| 29 | +| Generation_Last_Month | float | kWh | inverterYear[-2] | energy | |
| 30 | +| Inverter_Temperature | float | °C | inverterDetail | inverterTemperature | |
| 31 | +| Monthly_Energy_Used | float | kWh | inverterDetail | eMonth - gridSellMonthEnergy | |
| 32 | +| Monthly_Generation | float | kWh | inverterDetail | eMonth | |
| 33 | +| Power_Grid_Total_Power | float | W | inverterDetail | pSum | |
| 34 | +| Total_Energy_Purchased | float | kWh | inverterDetail | gridPurchasedTotalEnergy | |
| 35 | +| Total_Generation | float | kWh | inverterDetail | eTotal | |
| 36 | +| Total_On_grid_Generation | float | kWh | inverterDetail | gridSellTotalEnergy | |
| 37 | +| updateDate | integer | | inverterDetail | dataTimestamp | |
0 commit comments